1.
Biosci. j. (Online) ; 36(1): 51-60, jan./feb. 2020. tab
Article in English | LILACS | ID: biblio-1049194

ABSTRACT

This study aimed to evaluate, in the second cycle, the growth and production of 'Orelha-de-elefante Mexicana' prickly pear (Opuntia sp.) under complementary irrigation with treated domestic sewage. The experiment was carried out in the Milagre Settlement, municipality of Apodi-RN, Brazil, from June 2016 to February 2017. Five treatments were evaluated, corresponding to four irrigation frequencies (2.3, 7.0, 14.0 and 21.0 days) to apply an effluent depth of 3.5 mm, and the control, rainfed cultivation (without irrigation). The experimental design was randomized blocks, with four replicates. After preliminary-primary treatment, the domestic sewage showed acceptable chemical and physical characteristics for fertigation under the conditions adopted in the prickly pear cultivation. 234 days after the 1st cut in the plants, the following morphometric characteristics were measured: plant height and length, width, perimeter, thickness and number of primary and secondary cladodes, and biomass accumulation. Complementary irrigation with treated domestic sewage effluent applied at intervals of 2.3, 7.0, 14.0 and 21.0 days allowed satisfactory growth and production of 'Orelha-de-elefante Mexicana' prickly pear; without irrigation, its development was substantially hampered during the dry period. Complementary irrigation with 3.5 mm of domestic sewage effluent applied at intervals of 2.3, 7.0 and 14.0 days led to highest growth and biomass accumulation in 'Orelha-de-elefante Mexicana' prickly pear.


Objetivou-se com esse trabalho avaliar, no segundo ciclo, o crescimento e a produção da palma forrageira orelha-de-elefante (Opuntia sp), conduzida sob irrigação complementar, com esgoto doméstico tratado. O experimento foi realizado no Assentamento Milagre, município de Apodi/RN, no período de junho/2016 a fevereiro/2017. Foram estudados cinco tratamentos, sendo quatro frequências de irrigação (2,3; 7; 14 e 21 dias), para aplicar uma lâmina de 3,5 mm de efluente, e a testemunha, cultivo em sequeiro (sem irrigação). Utilizou-se o delineamento de blocos casualizados com quatro repetições. A água de esgoto doméstico após passar pelo tratamento preliminar-primário apresentou características químicas e biológicas aceitáveis para a fertirrigação nas condições utilizadas no cultivo da palma. Após 234 dias do 1º corte realizado na palma, foram feitas medições das características morfométricas: altura de planta, comprimento, largura, perímetro, espessura e número de cladódios primário e secundário e acúmulo de biomassa. A complementação hídrica realizada por irrigação com intervalos de 2,3; 7,0; 14,0 e 21,0 dias, viabilizou satisfatoriamente o crescimento e a produção da palma forrageira orelha de elefante que, sem irrigação, teve seu desenvolvimento bastante comprometido no período seco. A complementação hídrica com 3,5 mm de água de esgoto doméstico tratado por irrigação, com intervalos de 2,3; 7,0 e 14,0 promovem o maior crescimento e acúmulo de biomassa da palma forrageira orelha de elefante.


Subject(s)
Gray Water , Opuntia , Agricultural Irrigation
2.
Biosci. j. (Online) ; 35(6): 1839-1846, nov./dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1049135

ABSTRACT

In the semi-arid region of Brazil due to water scarcity, the use of alternative water sources is of vital importance, such as the use of saline waters and treated sewage effluents. Therefore, in the present work, the growth of sunflower plants irrigated with tap water and treated domestic sewage effluent, associated with organic fertilization was evaluated. The research was carried out in a protected environment at the Federal University of Campina Grande, Campus I, Campina Grande, PB. A completely randomized experimental design with factorial arrangement was used (4 x 2) + 2, with 5 repetitions. the treatments consisted of organic manure dosages (7.5, 10, 12.5 and 15% of manure on a weight basis) and two water sources (supply water and treated domestic sewage effluent). According to the results obtained, it can be indicated that the use of domestic sewage effluent for sunflower irrigation increased sunflower growth in relation to the use of water supply. The application of manure doses of 12.5 and 15% improved the early growth of the sunflower, with significant increases in the growth variables.


Na região semiárida do Brasil, devido à escassez de água, o uso de fontes alternativas de água é de vital importância, como o uso de águas salinas e efluentes de esgoto tratado. Portanto, no presente trabalho, avaliou-se o crescimento de plantas de girassol irrigadas com água da torneira e efluente de esgoto doméstico tratado, associado à adubação orgânica. A pesquisa foi realizada em ambiente protegido da Universidade Federal de Campina Grande, Campus I, Campina Grande, PB. Utilizou-se delineamento experimental inteiramente casualizado, com arranjo fatorial (4 x 2) + 2, com 5 repetições. Os tratamentos consistiram de dosagens de adubo orgânico (7,5; 10; 12,5 e 15% de esterco por peso) e duas fontes de água (água de abastecimento e efluente de esgoto doméstico tratado). De acordo com os resultados obtidos, pode-se indicar que o uso de efluente de esgoto doméstico na irrigação com girassol aumentou o crescimento do girassol em relação ao uso de água. A aplicação de doses de estrume de 12,5 e 15% melhorou o crescimento inicial do girassol, com aumentos significativos nas variáveis de crescimento.


Subject(s)
Gray Water , Helianthus , Manure
3.
Eng. sanit. ambient ; 24(4): 655-666, jul.-ago. 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1039779

ABSTRACT

ABSTRACT Several countries have developed tools with criteria and evaluations to grant, through the environmental certification, a more sustainable undertaking, with quality and productivity for its users. The tools were developed for different needs and objectives, which makes it difficult to make a direct comparison, in addition to having specific demands for each region. This study aims to make a comparative analysis between some tools of greater international knowledge and to propose new parameters for the water use and management category, taking into account the design and operational phase, the water distribution, and the demands for 2025. Consequently, this study proposed the creation of an exclusive environmental tool for the management and water use, providing a seal that may be applied to any project and adopted by water work systems as an incentive to reduce the consumption of drinking water, to use alternative sources, and to decrease liquid effluents.


RESUMO Vários países desenvolveram ferramentas com critérios e avaliações para garantir um empreendimento mais sustentável, com qualidade e produtividade para seus usuários, por meio de certificação ambiental. As ferramentas foram desenvolvidas para diferentes necessidades e objetivos, o que dificulta a comparação direta, além de haver demandas específicas para cada região. Este estudo teve como objetivo fazer uma análise comparativa entre algumas ferramentas de maior conhecimento internacional e propor novos parâmetros para a categoria de uso e gestão da água, levando em conta a fase de projeto e operação, a distribuição de água e as demandas para 2025. Consequentemente, este estudo propôs a criação de uma ferramenta ambiental exclusiva para a gestão e o uso da água, proporcionando um selo que pode ser aplicado a qualquer projeto e adotado pelas concessionárias de água como incentivo para reduzir o consumo de água potável, usar fontes alternativas e diminuir os efluentes líquidos.

4.
Eng. sanit. ambient ; 23(4): 665-674, jul.-ago. 2018. tab
Article in Portuguese | LILACS | ID: biblio-953275

ABSTRACT

RESUMO A pesquisa foi desenvolvida para avaliar o efeito da utilização de probiótico (Bacillus licheniformis, Bacillus cereus, Bacillus subitillis, leveduras e Saccharomyces cerevisiae e Saccharomyces boulardi) em rações para tilápias, nas fases de alevino e juvenil, submetidas a desafio sanitário sobre o desempenho, a composição bromatológica da carcaça dos animais e a qualidade da água. Foram utilizados 360 alevinos, com peso médio inicial de 2,91±0,37 g e comprimento médio inicial 3,30±0,27 cm. Os tratamentos consistiram de: T1) peixes cultivados em água limpa, alimentados com ração comercial, sem uso de probiótico; T2) peixes cultivados em água de esgoto doméstico tratado e alimentados com ração comercial, sem uso de probiótico; T3) peixes cultivados em condição semelhante ao T2, com ração acrescida de probiótico. Na avaliação dos parâmetros físico-químicos do esgoto sanitário tratado, independentemente da presença ou não de cepas probióticas, apresentam-se com elevada produtividade primária. O uso de probiótico (Bacillus licheniformis, Bacillus cereus e Bacillus subitillis; e leveduras - Saccharomyces cerevisiae e Saccharomyces boulardi) promove melhorias nos parâmetros de consumo de ração e taxa de crescimento específico em tilápias-do-nilo cultivadas em água tratada de esgoto doméstico, reduz a proporção de extrato etéreo no ganho de peso e eleva a proporção de proteína bruta no ganho de peso. Porém, não influencia o ganho de peso, a conversão alimentar aparente e a sobrevivência dos peixes. Os animais cultivados em água de esgoto sanitário tratado, independentemente do uso ou não das cepas probióticas, apresentam um maior teor de proteína e menor teor de gordura.


ABSTRACT The research was conducted to evaluate the effect of using probiotic (Bacillus licheniformis, Bacillus cereus, Bacillus subitillis, yeasts and Saccharomyces cerevisiae and Saccharomyces boulardi) in diets for tilapia, during the fingerling and juvenile stages, that underwent sanitary challenge on performance, chemical composition of the carcasses and water quality. We used three hundred and sixty fingerlings with initial average weight of 2.91±0.37 g and initial average length of 3.30±0.27 cm. The treatments were: T1) farmed fish in clean water, fed with commercial food without the use of probiotics; T2) fish reared in treated sewage water and fed with commercial food without the use of probiotics; T3) farmed fish in a condition similar to T2, with food plus probiotic. In the evaluation of physicochemical parameters of the treated sewage, regardless of the presence or not of probiotic strains, it presents a high primary productivity. The use of probiotics (Bacillus licheniformis, Bacillus cereus and Bacillus subitillis and yeasts - Saccharomyces cerevisiae and Saccharomyces boulardi) promotes improvements in the parameters of feed intake and specific growth rate in the Nile tilapia grown in treated water from sewage, reduces the proportion of lipids in weight gain and increases the proportion of crude protein in weight gain. However, it does not influence weight gain, feed conversion and fish survival. Fish grown in treated sanitary sewage, regardless of the use or not of probiotic strains have a higher protein content and lower fat content.

5.
Eng. sanit. ambient ; 23(4): 801-810, jul.-ago. 2018. tab, graf
Article in Portuguese | LILACS | ID: biblio-953276

ABSTRACT

RESUMO O módulo de fossa verde (MFV) corresponde a um modelo alternativo de tratamento de efluente domiciliar que considera o reúso da água em quintais produtivos, contribuindo para o saneamento rural. O presente estudo tem por escopo a avaliação de 70 unidades desses módulos instalados no semiárido brasileiro e inclui teste de qualidade sanitária dos vegetais cultivados, proposta de dimensionamento, taxa de acumulação do lodo produzido e avaliação do tempo de manutenção do MFV. O dimensionamento levou em conta o consumo de água, tendo sido avaliadas in loco a demanda hídrica para uma residência com (R1) e uma sem (R2) água canalizada. Além disso, foi mensurada a contribuição de esgoto e o coeficiente de retorno em cada caso. As amostras analisadas de tomate (Solanum esculentum), pimenta (Capsicum chinense), banana (Musa sp.) e da folha de malvarisco (Plectranthus amboinicus L.) apresentaram valores de coliformes termotolerantes inferiores a 10 UFC.g-1 e ausência de Salmonella sp., indicando que os produtos atendem aos padrões sanitários. Os consumos hídricos para R1 e R2 foram de 50 e 34 L.hab-1.dia-1, enquanto os valores referentes à produção de esgoto foram de 13,1 e 1,2 L.hab-1.dia-1, respectivamente. Isso indica coeficientes de retorno equivalentes a 26 e 3% para R1 e R2, simultaneamente, o que difere substancialmente do valor comumente preconizado (80%). O sistema apresenta baixa demanda de manutenção: remoção do lodo da câmara de digestão a cada cinco anos e três meses, em média.


ABSTRACT The green pit module corresponds to an alternative model to treat domestic sewage in rural areas, which considers water reuse in productive yards, contributing to rural sanitation. The present investigation has assessed the green pit module performance based on 70 modules installed in the semiarid region of Brazil and includes sanitary quality test of cultivated vegetables, sizing proposal, rate of accumulation of the sludge produced and evaluation of the maintenance period of the green pit module. A design method was presented, which is based on water consumption, and has been assessed on site for two kinds of homes: those with (R1) and without (R2) tap water supply. In addition, we measured the sewage contribution and return coefficient for each case. The analyzed samples of tomato (Solanum esculentum), pepper (Capsicum chinense), banana (Musa sp.) and "malvarisco" leaves (Plectranthus amboinicus L.) presented low levels of coliform (below ten colony-forming units per gram) and absence of Salmonella sp., which complies with the Brazilian sanitation legislation. The water consumption for R1 and R2 were 50 and 34 L.resident-1.day-1, whereas sewage per capita production totaled 13.1 and 1.2 L.resident-1.day-1 for R1 and R2, respectively. This indicates return coefficients of 26 and 3% for R1 and R2, respectively, which differs significantly from the usually recommended value (80%). The system presents low maintenance demand: the sludge should be removed every 5.3 years, on average.

6.
Eng. sanit. ambient ; 22(1): 95-102, jan.-fev. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-840383

ABSTRACT

RESUMO Os efeitos das alterações climáticas e a crescente demanda de água para os variados consumos vão levar ao reúso de águas residuárias tratadas (ART). A recarga de aquíferos com ART pode constituir uma alternativa para o restabelecimento de volumes de água subterrânea que poderão ser utilizados para satisfazer parte daquelas atividades, especialmente em regiões de escassez de água ou onde sua qualidade não é adequada para uso. Uma pesquisa de dois anos realizada na estação de tratamento de esgoto de Vila Fernando (Guarda, Portugal) mostrou que as caraterísticas das ART são adequadas para que o efluente seja infiltrado no solo visando à recarga de aquífero. Como a área em estudo é vasta e dada a necessidade de considerar várias restrições técnicas, ambientais e econômicas, foi aplicada uma análise multicritério baseada em Sistemas de Informação Geográfica para encontrar o local mais adequado para a infiltração de ART. Recolheu-se uma amostra de solo para análise, na Quinta de Gonçalo Martins (Guarda, Portugal), tendo os resultados indicado que tal solo apresentava características favoráveis à infiltração de ART.


ABSTRACT The effects of climate change and the increasing demand of water for domestic, industrial and agricultural uses will lead to the use of treated wastewater (reclaimed water). The aquifer recharge with reclaimed water can be an alternative for restoring volumes of water to aquifers, which may afterwards be used to satisfy those demands, especially in regions with water scarcity or where water presents poor quality. A two-year research conducted in the sewage treatment plant of Vila Fernando (Guarda, Portugal) has shown that the characteristics of reclaimed water are adequate to be infiltrated into the soil for aquifer recharge. As the study area for infiltration was very large and it was necessary to consider several technical, environmental and economic constraints, a multi-criteria analysis based on Geographic Information Systems was used in order to find the most suitable site for reclaimed water infiltration. Soil sample was collected at Quinta Gonçalo Martins (Guarda, Portugal) for analysis, and the results have indicated that the site has favorable characteristics for reclaimed water infiltration.

7.
Eng. sanit. ambient ; 22(1): 179-186, jan.-fev. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-840387

ABSTRACT

RESUMO No Brasil, cerca de 32.700 postos de lavagem de veículos consomem 3,7 milhões de m3/mês-1, média de 60 L por veículo. Esse consumo poderia ser minimizado, se o efluente fosse devidamente tratado e reutilizado. Como diversos tipos de efluentes têm sido eficientemente tratados por técnicas eletroquímicas, como a eletrocoagulação (EC) e a eletroflotação (EF), o objetivo principal deste estudo foi desenvolver um sistema de tratamento de efluentes de lavagem de carros por EC, usando eletrodos de alumínio. Parâmetros como pH inicial, corrente elétrica aplicada e tempo de eletrólise foram otimizados por meio de análises físico-químicas e estatísticas. Em sua condição ótima, pH 5, corrente elétrica de 3,5 A e tempo de 20 minutos, o sistema conseguiu reduzir em 73% a demanda química de oxigênio (DQO), 58% de surfactantes e no mínimo 90% a turbidez e os sólidos suspensos totais (SST). Além da simples implantação e operação, a técnica mostrou-se eficiente na recuperação desse tipo de efluente, podendo ser utilizada em sistemas de reúso de água de lavagem de veículos.


ABSTRACT In Brazil, about 32,700 vehicle washing stations consume 3,7 million m3 per month-1, average of 60 L per vehicle. Consumption could be minimized if the effluent was properly treated and reused. As different types of effluents have been effectively treated by electrochemical techniques, such as electrocoagulation (EC) and electrocoagulation (EF), the main objective of this study was to develop a treatment system of carwash wastewater, by EC using electrodes aluminum. Parameters like the initial pH, applied electric current and electrolysis time were optimized by means of physical-chemical analysis and statistics. In its optimum condition, pH 5, electrical current of 3,5 A and time of 20 minutes, the system has managed to reduce by 73% the chemical oxygen demand (COD), 58% of surfactants and a minimum of 90% turbidity and total suspended solids (TSS). Besides the simple installation and operation, the technique was efficient in the recovery of this type of effluent and can be used in reuse system carwash water.

8.
Ciênc. rural ; 47(7): e20151605, 2017. tab, graf
Article in English | LILACS | ID: biblio-839878

ABSTRACT

ABSTRACT: This study aimed to evaluate the obstruction of non-pressure compensating emitters using treated sewage effluent (TSE) for irrigation. A drip irrigation system with six models of emitters (encoded) was installed in level field conditions. TSE coming from a sewage treatment station was used as irrigation water after being filtered through a disc filter (120 mesh). Seven flow rate evaluations of drippers operating at 100kPa were performed (0, 100, 200, 300, 400, 500 and 600h of operation). The experimental design was randomized in a 6×7 factorial arrangement (6 models and 7 times), with four repetitions, and Tukey’s test was used to compare means. Relative flow rate (Qr), the flow rate coefficient of variation (CVQ) and degree of clogging (GE) were determined. There was a reduction in flow rate in five dripper models, which are susceptible to clogging. The model with rated flow stood out against the others, showing a Qr of 100.52%, CVQ of 2.76% and GE of 0.49%. The use of TSE changed the Qr of the drippers after 600h of operation.


RESUMO: Objetivou-se avaliar a obstrução de gotejadores não autocompensantes utilizando efluente de esgoto tratado (EET) para irrigação. Um sistema de irrigação por gotejamento com seis modelos de gotejadores (codificados) foi instalado em nível e em condições de campo. Como água de irrigação foi utilizado EET, originado de estação de tratamento de esgoto, filtrado por um filtro de disco (120 mesh). Foram realizadas sete avaliações da vazão dos emissores (0, 100, 200, 300, 400, 500 e 600h de funcionamento), operando a 100kPa. O experimento foi montado em delineamento casualizado, com arranjo fatorial 6x7 (6 modelos e 7 tempos), com 4 repetições e teste de Tukey para comparação das médias. Foram determinados a vazão relativa (Qr), o coeficiente de variação de vazão (CVQ) e o grau de entupimento (GE). Observou-se redução na vazão em cinco modelos de gotejadores, sendo estes suscetíveis ao entupimento. O modelo com maior vazão nominal destacou-se perante os demais, apresentando Qr de 100,52%, CVQ de 2,76% e GE de 0,49%. A utilização de EET alterou a Qr dos gotejadores após 600h de funcionamento.

9.
Arq. bras. med. vet. zootec ; 67(1): 255-264, 2/2015. tab, fig
Article in Portuguese | LILACS | ID: lil-741113

ABSTRACT

Neste trabalho estudou-se a utilização de esgotos domésticos tratados na criação do peixe ornamental molinésia (Poecilia sp.), observando o desempenho zootécnico e avaliando-se o bem-estar dos peixes cultivados. Foram testados três tratamentos: ET - abastecido com esgoto tratado em lagoas de estabilização; ED - abastecido com esgoto tratado e água de poço diluídos em iguais proporções; AB - abastecido com água de poço. Por meio dos resultados dos parâmetros físico-químicos, observou-se que o esgoto doméstico tratado em lagoas de estabilização oferece condição para se realizar o cultivo da espécie, com melhor desempenho quando diluído em água. Em todos os parâmetros de rendimento zootécnicos avaliados, o tratamento que utilizou o esgoto tratado diluído foi o que apresentou os melhores resultados. Dentre os indicadores de bem-estar observados, apenas a avaliação histopatológica foi capaz de fornecer resultado conclusivo, o qual apontou o tratamento que utilizou esgoto tratado diluído como o que proporcionou maior conforto à espécie cultivada. As características ornamentais dos peixes cultivados não sofreram influência do uso do esgoto doméstico tratado, observando-se que os padrões de coloração e formato de nadadeiras não foram alterados.


This work evaluated the treated sewage reuse in ornamental molly fish creation, evaluating the zootechnical performance and animal welfare. Three treatments were tested: ET - supplied with treated sewage; ED - supplied with sewage and raw water in the same proportion; AB - supplied with raw water. The physical-chemical results indicated that the treated sewage from stabilization ponds was adequate for the species cultivation only when diluted in raw water. Among the welfare indicators, only histopathological evaluation was able to provide conclusive results, which showed that the treated sewage diluted treatment was the best in terms of comfort for the cultivated species. The ornamental characteristics of farmed fish were not influenced by the use of treated sewage, in which the patterns of color and shape of fins were not changed.


Subject(s)
Animals , Animal Welfare/trends , Aquaculture/methods , Fishes/growth & development , Domestic Effluents
10.
Biosci. j. (Online) ; 31(1): 215-226, jan./fev. 2015.
Article in Portuguese | LILACS | ID: biblio-963846

ABSTRACT

Devido à pouca informação sobre a capacidade de extração de nutrientes do solo por forrageiras fertirrigadas com efluentes, o presente trabalho teve como objetivo avaliar a capacidade de extração de macronutrientes e sódio do solo pelas forrageiras Tifton 85 (Cynodon spp) e Capim Marandú (Brachiaria brizantha) fertirrigadas com esgoto doméstico tratado em três ciclos de produção, em condições de casa de vegetação. Os experimentos foram montados num delineamento inteiramente casualizado, sendo um para cada espécie, ambos no esquema em parcelas subdivididas 4x3 com 5 repetições, sendo quatro ratamentos fertirrigados com esgoto doméstico tratado nas dosagens de 20, 40, 60 e 80 kg ha-1 de nitrogênio nas parcelas e nas subparcelas, três ciclos de produção onde foram realizados cortes no material vegetal das forrageiras, sempre aos 30 dias após o término da aplicação do esgoto doméstico tratado. Após cada corte, os tratamentos foram novamente aplicados e no material vegetal cortado foram quantificados os teores foliares dos macronutrientes e sódio extraídos do solo pelas forrageiras. Os resultados obtidos demonstraram que a aplicação de nitrogênio por meio do esgoto doméstico tratado e os ciclos de produção (cortes) afetaram positivamente a produção de massa seca e a extração dos macronutrientes e sódio pelas plantas de Tifton 85 e de Capim Marandú.


Due to limited information on the ability to extract nutrients from the soil by forage fertigated with effluent, the present study aimed to evaluate the extraction capacity of soil macronutrients and sodium by fodder Tifton 85 (Cynodon spp) and Marandu Grass (Brachiaria brizantha) fertigated with treated domestic sewage on three production cycles in greenhouse conditions. The experiments were performed in a completely randomized design, one for each species, both in split plot layout 4x3 with 5 repetitions, four fertigation with treated domestic sewage at dosages of 20, 40, 60 and 80 kg ha-1 nitrogen in plots and subplots, three production cycles where cuts were made in the forage plant material, always 30 days after the completion of the application of treated domestic sewage. After each cut, the treatments were applied again and cut plant material were quantified foliar levels and sodium extracted from the soil by forage. The results showed that the application of nitrogen through the treated domestic sewage and production cycles (cuts) positively affected the dry matter production and extraction of macronutrients and sodium by plants and Tifton 85 on the Marandú Grass.


Subject(s)
Soil , Domestic Effluents , Brachiaria , Cynodon , Nutrients , Wastewater , Sewage , Food
11.
Eng. sanit. ambient ; 16(1): 45-54, mar. 2011. graf, tab
Article in Portuguese | LILACS | ID: lil-582645

ABSTRACT

Este trabalho teve como objetivo avaliar a sustentabilidade ambiental do uso de esgoto doméstico tratado na piscicultura por meio do Índice de Sustentabilidade Ambiental para Reúso em Piscicultura (ISA RP), do Índice de Qualidade de Água para Reúso em Piscicultura (IQA RP) e do custo ambiental (entropia). Observou-se, por meio do custo ambiental, que a piscicultura convencional causou a deterioração da qualidade da água que foi utilizada. Constatou-se que o sistema de piscicultura utilizando esgoto tratado, sem usar aeração, não causou efeito deletério significante à qualidade da água de reúso (efluente da estação de tratamento de esgoto - ETE). O sistema de piscicultura usando esgoto tratado, com aeração, resultou na melhoria de sua qualidade, quando comparado com o efluente da estação de tratamento, significando que essa prática resultou em um polimento no líquido utilizado. Ambos os sistemas de reúso de águas mostraram-se ambientalmente sustentáveis, o que indica a potencialidade do uso de esgoto doméstico tratado como fonte de água e alimento natural para a piscicultura.


This work aimed to evaluate the environmental sustainability of the treated sewage reuse on aquaculture by using the Environmental Sustainability Index of Aquaculture Reuse (ESI AR), Water Quality Index of Aquaculture Reuse (WQI AR) and environmental cost (entropy). For conventional aquaculture, a water quality deterioration of the fish tanks was observed by the environmental cost. When treated sewage was used in tanks without external aeration, it was not verified a remarkable water quality deterioration. However, for the tanks externally aerated and fed with treated sewage there was a water quality improvement, in other words a polishing step was taking place. All the systems analyzed showed to be environmentally sustainable, which indicates that the treated sewage can be considered a good water source for aquaculture.

12.
Ciênc. agrotec., (Impr.) ; 34(4): 983-989, July-Aug. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-556989

ABSTRACT

A dessalinização por osmose reversa tem sido bastante utilizada para o tratamento de água salobra, possibilitando a sua utilização para o consumo humano, especialmente em regiões semiáridas. Esse processo tem um fator limitante que é a produção de um rejeito de água com alta salinidade. Com o objetivo de avaliar os efeitos da utilização de água de rejeito da dessalinização no cultivo de alface cultivar Vera (Lactuca sativa L.) em sistema hidropônico NFT foi conduzido um experimento em casa de vegetação no departamento de ciências ambientais da UFERSA, em delineamento em blocos casualizados, com seis tratamentos e quatro repetições. Os níveis de salinidade da água entre os tratamentos foram obtidos com, ou sem a necessidade de diluição da água de rejeito da dessalinização acrescido da solução nutritiva com salinidade de 1 dS m-1 (100 por cento de água potável de abastecimento - 1,4 dS m-1; 85 por cento abastecimento e 15 por cento água de rejeito - 1,9 dS m-1; 75 por cento água de rejeito + 25 por cento água de abastecimento - 2,7 dS m-1; 50 por cento água de rejeito e 50 por cento água de abastecimento - 3,8 dS m-1; 25 por cento água de rejeito e 75 por cento água de abastecimento - 4,9 dS m-1 e água de rejeito coletada no dessalinizador - 5,5 dS m-1. Os parâmetros analisados foram área foliar, diâmetro do caule, número de folhas, peso de matéria fresca e o peso de matéria seca. Todas as variáveis estudadas foram influenciadas negativamente de forma linear pelo efeito da concentração de sais na água de irrigação, sendo que a área foliar e a matéria fresca da parte aérea são as que melhor representam a sensibilidade ao estresse salino na cultivar estudada, tendo a produção em termos de matéria fresca uma redução de 94,83 por cento, ao se elevar a CEa de 1,4 a 5,5 dS m-1.


The desalination process by reverse osmosis was used for the treatment of brackish water, making possible the usage human consume in semiarid zones. This process has a limiting factor: it produces wastewater with high salinity. To evaluate the effect of the use of desalted water on lettuce (Lactuca sativa L.) production cv. Vera in a NFT hydroponics system an experiment was carried out in a greenhouse located at the Departament of Environmental Sciences of the Universidade Federal Rural do Semi-Árido, in a statistical test with completely randomized blocks with four repetitions and six treatments. The salinity level of the war between treatments was checked with and without dilution of the wastewater, adding the nutrient solution with salinity of 1 dS m-1 (100 percent public water supply - 1.4 dS m-1; 85 percent water supply and 15 percent wastewater - 1.9 dS m-1; 75 percent wastewater + 25 percent water supply - 2.7 dS m-1; 50 percent wastewater e 50 percent water supply - 3.8 dS m-1; 25 percent wastewater and 75 percent water supply - 4.9 dS m-1 and wastewater gathered from desalter - 5.5 dS m-1. The number of leaves, diameter of the stem, fresh and matter biomass and leaf area were analyzed. All the analyzed variables were negatively influenced in a linear way by the effect of the concentration of salts in irrigation water. Biomass and leaf area are more sensitive to saline stress in the cultivar studied, and fresh matter production was reduced by 94.83 percent, when CEa was increased from 1.4 to 5.5 dS m-1.

13.
São Paulo; s.n; 2010. [135] p. ilus, tab, mapas.
Thesis in Portuguese | LILACS | ID: lil-575216

ABSTRACT

A diminuição da disponibilidade de água de boa de qualidade em nível mundial é resultado, entre outros fatores, do consumo elevado exercido pela agricultura irrigada. A fim de minimizar os impactos ocasionados por essa atividade aos recursos hídricos, muitos países demonstram a viabilidade do emprego de efluentes de esgoto tratado na agricultura. Contudo, esta prática oferece riscos à saúde pública através dos organismos patogênicos capazes de sobreviver no esgoto. Entre estes patógenos a OMS destaca os protozoários e os helmintos parasitas do homem, pelo fato de apresentarem maior período de sobrevivência em condições adversas e alto poder de infecção. O presente trabalho tem como objetivo realizar um levantamento qualitativo e quantitativo dos parasitas intestinais de importância sanitária presentes no esgoto afluente, no efluente tratado e no efluente desinfetado de duas estações de tratamento localizadas na cidade de Piracicaba. A ETE Cecap é composta por um sistema australiano com uma lagoa anaeróbia, lagoas facultativas primária e secundária e tratamento por filtração e desinfecção por cloração. A ETE Piracicamirim é constituída por reatores UASB seguidos por lagoa aerada, decantadores secundários de lodo ativado, tratamento por filtro de areia e desinfecção por radiação ultravioleta. Entre maio de 2008 e dezembro de 2009 foram coletas amostras do esgoto bruto e dos efluentes tratado e desinfetado, seguindo as orientações de AYRES e MARA (1996). As técnicas de preparo e análises parasitológicas foram realizadas segundo YANKO (1987) e WHO (1999). A ETE Cecap apresentou uma frequência de amostras positivas de 40 por cento para o efluente desinfetado, sendo Toxocara sp o parasita mais presente com 46,17 ovos/l. A média de ovos de helmintos para o período de estudo foi 3,78 ovos/l de efluente desinfetado. A ETE Piracicamirim apresentou uma frequência de 100 por cento para o efluente desinfetado. Ascaris sp foi o parasita mais encontrado nos três pontos...


Decreased availability of good water quality worldwide is a result, among other factors, high consumption exerted by irrigated agriculture. In order to minimize the impacts caused by this activity to water, many countries demonstrate the viability of using treated sewage effluent in agriculture. However, this practice provides a public health risk through the pathogens can survive in sewage. Among these pathogens, WHO stresses the protozoa and helminths of human, because they presented greater period of survival in adverse conditions and high power of infection. This paper aims to evaluate the quality and quantity of intestinal parasites of sanitary importance present in the raw sewage in the treated effluent and disinfected from two treatment plants located in the city of Piracicaba. The sewage treatment plant CECAP comprises an Australian system with an anaerobic pond, facultative ponds primary and secondary treatment by filtration and disinfection by chlorination. The sewage treatment plant Piracicamirim consists of UASB followed by aerated lagoon, activated sludge secondary clarifiers, treatment by sand filter and disinfection by ultraviolet radiation. Between May 2008 and December 2009 were collected and samples of raw sewage effluent treated and disinfected, following the guidelines of AYRES and MARA (1996). The techniques of preparation and analysis were performed according parasitological YANKO (in 1987) and WHO (1999). CECAP showed rates of positive samples of 40 per cent for the effluent disinfected with Toxocara sp parasite more present with 46.17 eggs/l. The mean helminths eggs for the study period was 3.78 eggs/l effluent disinfected. Piracicamirim showed rates of 100 per cent for the effluent disinfected. Ascaris sp was the parasite most commonly found in the three collection sites...


Subject(s)
Eukaryota/isolation & purification , Helminths/isolation & purification , Parasitology , Public Health , Water Purification , Water Microbiology , Water Quality , Water Quality Standards , Parasitic Diseases
14.
Eng. sanit. ambient ; 14(2): 215-222, abr.-jun. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-520306

ABSTRACT

A utilização de processos de membrana em Engenharia Ambiental tem expandido de forma significativa nos últimos anos e, tendo em vista a importância da possibilidade de otimização da sua operação com vistas à produção máxima de permeado em função do tempo, este trabalho teve por objetivo definir uma técnica de otimização da operação de sistemas de ultrafiltração mediante o estudo de ciclos de operação e lavagem. Os ensaios experimentais foram efetuados tendo-se empregado duas membranas de ultrafiltração com diferentes pesos moleculares de corte e, com base nos resultados experimentais, foi possível a proposição de um modelo matemático que permitiu a otimização da operação de sistemas de ultrafiltração, o que possibilitou o aumento da produção do volume de permeado em cerca de 14 por cento.


The utilization of membrane processes in Environmental Engineering has expanded significantly in the last few years. This paper had the primary objective of defining an optimization technique for ultrafiltration (UF) membrane operation by studying UF membrane operation and backwashing cycles. The main importance of UF operation optimization is to maximize permeation production as a function of time. Experimental tests were conducted with two UF membranes with different molecular weight cutoff. The experimental results led to the proposition of a mathematical model for the optimization of UF systems; such optimization conducted in practice to an increase of 14 percent in the permeate volume production.

15.
Eng. sanit. ambient ; 14(2): 235-244, abr.-jun. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-520308

ABSTRACT

A discussão acerca da viabilidade técnica, econômica e ambiental do reúso da água em processos industriais tem sido uma preocupação constante. Neste trabalho propõe-se uma alternativa simplificada para o tratamento de efluentes com vistas ao seu reúso em uma indústria de reciclagem de plásticos. A água, no presente caso, é componente fundamental para o processo, já que participa como elemento de remoção de detritos e impurezas que contaminam a matriz da matéria-prima utilizada, proveniente, principalmente, de aterros sanitários e lixões. As embalagens plásticas recicladas pela indústria em questão são, em sua grande maioria, de uso doméstico e, em menor escala, frascos contaminados com óleos lubrificantes. Os resultados demonstraram a viabilidade do tratamento através de processo físico-químico por coagulação, floculação, decantação e filtração em manta geotêxtil, com o uso do hidroxicloreto de alumínio (PAC) como coagulante, soda cáustica (50 por cento) como alcalinizante e polieletrólito como auxiliar de floculação e desidratação do lodo, bem como a exequibilidade do reúso dos efluentes em circuito fechado.


The discussion about technical, economical and environmental feasibility of water reuse in industrial process has been a constant concern. This paper purposes a simplified choice for waste water treatment seeking reuse in a plastic recycle industry. The water, in this case, is a prime component because it is the main element for the debris and impurities removal that contaminates the matrix of plastic raw material, which comes, mostly, from landfill and waste disposals. The recycled plastic packages, from the company that had been used for this research, come mostly from domestic use and, in a minor scale, the plastic package contaminated by lubricant oil. The final results show feasible for the treatment through physical-chemical process by coagulation, flocculation, decantation and filtration on geotextile, with the use of aluminum hidroxichloride (PAC) as coagulant, sodium hydroxide as alkaliner, polyelectrolyte as auxiliary on flocculation and slush dehydration, as well as the workability of the effluents reuse under a closed circuit proved itself the technical, economical and environmental feasibility.

16.
Ciênc. agrotec., (Impr.) ; 33(spe): 1752-1757, 2009. tab, ilus
Article in Portuguese | LILACS | ID: lil-542321

ABSTRACT

Este experimento foi conduzido na Unidade I do Centro Federal de Educação Tecnológica de Uberaba (CEFET-Uberaba), em Uberaba, MG, durante o ano de 2006. Conduziu esse experimento, com o objetivo de avaliar a influência da concentração de sólidos totais contidos na água residuária de suinocultura: nas perdas de cargas ocorridas no sistema, na uniformidade de distribuição, na distribuição de sólidos totais ao longo do raio de alcance do aspersor, no raio de alcance do aspersor. Os tratamentos constaram das concentrações de sólidos totais contidos em cada camada da lagoa retirada durante o ensaio. Utilizou-se um sistema de irrigação autopropelido da marca Metal Lavras, modelo mini 63/150, equipado com um canhão da marca Plona modelo RL 250 e um sistema de bombeamento composto por uma bomba da marca Schneider modelo MSA-22 R 1 »" acoplada a um motor trifásico de 15 cv. As perdas de carga foram influenciadas diretamente pela concentração dos sólidos contidos na água residuária, chegando a acréscimos de 30,77 por cento na adutora, 13,59 por cento na turbina e 22,02 por cento na mangueira, para a maior concentração de sólidos avaliada em relação a água sem resíduo. Na uniformidade de distribuição e no raio de alcance do aspersor, não houve influência significativa da concentração de sólidos. Na distribuição de sólidos ao longo do raio de alcance do aspersor, observou-se uma maior concentração nos coletores mais afastados do aspersor.


This experiment was carried out at Unit I at the Federal Technological Education Center in Uberaba (CEFET-Uberaba-MG), during the year of 2006. The aim was to evaluate the influence of solids concentration in swine wastewater on charge losses of the irrigation system, on water distribution uniformity, on distribution of solids along the sprinkler radius of throw. The treatment levels were solid concentration at different depths of a water pond. The irrigation self propelled system is manufactured by Metal Lavras, model mini 63/150, with a gun sprinkler model Plona RL 250 and a pump system with a Schneider unit model MSA-22R 1/14" with a three phase electrical engine 15 HP. The charge losses were influenced by the solids concentration increasing the losses in 30.77 percent at the main pipe, 13.59 percent at the turbine and 22.02 percent at the plastic hose, for the largest solid concentration compared to water only. At water distribution uniformity and radius of throw statistical differences were not observed. One observed that solid application varied along the radius of throw, being larger quantities applied at the larger distances.

17.
Estud. av ; 22(63): 131-158, 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-490002

ABSTRACT

A política de importar água de bacias cada vez mais distantes para satisfazer o crescimento da demanda teve início há mais de dois mil com os romanos, dando origem aos seus famosos aquedutos. Esse é o "velho paradigma" que persiste ainda hoje, resolvendo, precariamente, o problema de abastecimento de água de uma região, em detrimento daquela que a fornece. A transferência sistemática de grandes volumes de água de fontes distantes, gerando volumes adicionais de esgoto, não pode mais ser aceita, tanto do ponto de vista econômico como do ambiental. Um novo paradigma, baseado nos conceitos de Conservação e Reúso de Água deve evoluir, para minimizar os custos e os impactos ambientais associados a projetos de transposição de bacias. A tecnologia e os fundamentos ambientais, de saúde pública e gerenciais, hoje consagrados, permitem fazer uso dos recursos disponíveis localmente, mediante programas de gestão adequada da demanda, e da implementação da prática de reúso de água.


Subject(s)
Wastewater , Conservation of Natural Resources , Water Resources , Brazil
18.
Eng. sanit. ambient ; 12(3): 305-316, jul.-set. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-466566

ABSTRACT

Com o objetivo de reduzir o consumo de água e o descarte do efluente tratado de uma indústria metal-mecânica foi proposta a avaliação técnica e econômica de cinco tecnologias de tratamento que pudessem proporcionar a reutilização do efluente. Foram levantados quatro locais para reúso e sugeridos critérios para cada um deles. Foi constatado que na adsor-ção com carvão ativado e na osmose reversa o efluente tratado por estes processos poderia ser reutilizado nos locais propostos e, com vazão de reúso de 2,5m³/h, os custos ficaram em US$ 1,14/m³ e US$ 1,70/m³ respectivamente. Para o ozônio e o dióxido de cloro, mesmo desinfetando o efluente, obteve-se apenas resultados satisfatórios, com custo de US$ 0,54/m³ e US$ 0,71/m³ respectivamente. Na coagulação/floculação todos os parâmetros analisados atenderam a dois locais de reúso, com exceção dos SDT e se obteve custo de US$ 1,57/m³


With the objective to reduce the water consumption and the discharge of effluents in a metal industry, a technical and economical evaluation of five treatment technologies was proposed in order to reuse the effluents. Four sites for water reuse were chosen and for each of them criteria were suggested. It was evidenced that in the adsorption with activated carbon and reverse osmosis the effluent treated by these processes could be reused and, with the flowrate projected of 2.5m³/h, the cost attained US$ 1.14/m³ and US$ 1.70/m³ respectively. For the ozone and chlorine dioxide, even so the effluent was disinfected, gave only satisfactory results and the cost attained US$ 0.54/m³ and US$ 0.71/m³ respectively. For the treatment with coagulation/flocculation, all the analyzed parameters were successful in two reuse places, with exception of the TDS. The cost for this technology attained US$ 1.57/m³


Subject(s)
Charcoal , Chlorine Dioxide , Flocculation , Metalmechanic Industry , Ozone , Reverse Osmosis , Wastewater Use